The Wade CS1800 is a circular precast concrete sump with an approximate brimful capacity of 5,280 L. Its proposed design includes a reinforced concrete base with a projecting foot for suitable below-ground collection and holding applications, subject to final design confirmation.
The Wade CS1800 is a circular precast concrete sump proposed for below-ground collection or holding applications. It has a 1,800 mm internal diameter, an overall height of 2,275 mm and an approximate brimful capacity of 5,280 L.
The proposed construction uses a precast concrete cylinder and reinforced concrete base that extends beyond the cylinder to form a projecting anti-flotation foot. This is a design feature, not a confirmed anti-flotation performance rating.
Potential applications include stormwater and wastewater collection, agricultural effluent holding and pump sumps. Suitability depends on the liquid, site conditions and completed design. Pipe connections and access arrangements can be discussed for each project.
Discuss inlet and outlet pipe positions, pump equipment and clearances, access and cover arrangements, installation depth, groundwater conditions and other project requirements with Wade.
Also see the Wade 1500 Concrete Sump (CS1500) or explore our Concrete Manhole Risers for additional diameters, depths and configurations.
Wade can also manufacture custom solutions to suit specific project requirements.
| Model | CS1800 |
|---|---|
| Approximate brimful capacity | 5,280 L |
| Internal diameter | 1,800 mm |
| Internal radius | 900 mm |
| Overall height | 2,275 mm |
| Height above base | 2,075 mm |
| Concrete cylinder length | 2,175 mm |
| Cylinder embedment into base | 100 mm |
| Concrete base thickness | 200 mm |
| Overall base / foot diameter | 2,340 mm |
| Overall base / foot radius | 1,170 mm |
| Construction | Precast concrete cylinder with reinforced concrete base |
| Base configuration | Projecting anti-flotation foot |
| Top | Open; access or cover requirements to be specified |
Dimensions and capacities are based on proposed Wade configurations and are subject to final design confirmation. Capacities are approximate brimful volumes. Suitability for the intended application, including watertightness, chemical exposure, groundwater and structural requirements, should be confirmed.
Contact Wade with the intended application, site location and any drawings or specifications. Groundwater and anti-flotation requirements, installation conditions and any structural or containment requirements need to be established before manufacture.