Wade Precast Concrete Wingwalls

Made-to-order precast concrete wingwalls for culvert inlets, outlets and drainage infrastructure. Manufactured in Dargaville, Northland, with dimensions and configurations tailored to project requirements. Contact Wade with your drawings or specifications for a quotation.

Made to suit your project
Custom pipe openings
Inlet & outlet applications
Manufactured in Northland

Precast Wingwalls for Culverts and Drainage

Wade Concrete Products manufactures precast concrete wingwalls for culvert inlets and outlets, stormwater drainage systems and civil infrastructure projects. Wingwalls help retain the surrounding ground at the end of a culvert and provide a defined transition for water entering or leaving the pipe.

Our wingwalls are made to order, allowing the dimensions and configuration to be considered for each project. Depending on the requirements, designs can incorporate splayed side walls, concrete aprons, headwalls, cast-in heels or toes, and pipe openings formed to suit the intended connection.

Precast manufacture can also reduce the need for on-site formwork and concrete placement compared with constructing the entire structure in situ. Wingwalls can be considered for farm crossings, rural drainage, roading, subdivisions and other civil works.

Wade manufactures precast concrete products in Dargaville, Northland. Whether you’re working from an engineering drawing, a council standard detail or an existing product specification, send us the information and we can assess what is practical to manufacture.

Wade Concrete Precast Wingwalls (2)
CONFIGURATIONS & OPTIONS

Wingwall Sizes and Custom Configurations

Wade manufactures precast concrete wingwalls to suit individual project requirements. The table below lists Wade wingwall codes by their maximum nominal pipe diameter. Each wingwall is made to order, with the pipe opening formed to suit the specified pipe size and connection.

Wade code Maximum nominal pipe diameter
WW200 200 mm
WW300 300 mm
WW600 600 mm
WW750 750 mm
WW900 900 mm
WW1050 1,050 mm
WW1350 1,350 mm
WW1800 1,800 mm
WW2050 2,050 mm
WW-CUSTOM Other sizes and configurations

The number in each WW code indicates the maximum nominal pipe diameter for that wingwall size. Smaller pipes can also be accommodated, with openings cast to suit the specified pipe dimensions. Final wingwall dimensions, structural requirements and connection details are confirmed for each project. All sizes are made to order and are subject to design and manufacturing assessment.

Custom Configurations

Depending on the project requirements, Wade can consider variations in wall height, overall width, apron dimensions, pipe openings and wingwall geometry.

Design options that can be considered include:

  • Pipe openings: Formed to suit the required pipe dimensions and connection arrangement.

  • Splayed side walls: Angled walls to provide a transition between the culvert and surrounding ground or drainage channel.

  • Concrete aprons: Incorporated where required by the project design.

  • Cast-in heels or toes: Considered where the structural design requires them.

  • Lifting anchors: Suitable cast-in lifting provisions where specified and appropriately designed.

  • Energy-dissipating baffles: Considered where required by a supplied hydraulic design.

These are potential manufacturing options rather than standard features included in every wingwall.

Working from an Existing Specification?

If your project already specifies a particular wingwall, send us the product reference or engineering drawing.

Wade can review the dimensions and technical requirements and provide a quotation for a suitable precast alternative where practical. This includes requests based on council standard drawings.

Any proposed alternative must satisfy the project’s engineering requirements and obtain the necessary approvals.

product photos

TECHNICAL DETAILS

Specifications

Additional information

Wade code

WW600

Nominal pipe size

600 mm

Overall front width

2,351 mm

Overall rear width

1,011 mm

Overall depth

880 mm

Overall height

1,250 mm

Front internal width

2,150 mm

Rear internal width

810 mm

Internal apron depth

745 mm

Headwall height above apron

1,000 mm

Information

Dimensions are indicative and based on the WW600 model. Final dimensions and manufacturing specifications are subject to confirmation.

Other options

Also available to suit 200 mm, 300 mm, 750 mm, 900 mm, 1,050 mm, 1,350 mm, 1,800 mm and 2,050 mm nominal pipe sizes, with custom sizes and configurations available on request.

Wade Concrete Precast Wingwalls (1)
IMPORTANT INFORMATION

Planning and Ordering Your Wingwalls

Information for Quotation

To help us assess your requirements, provide the nominal pipe diameter, pipe material, quantity required and any available dimensions or engineering drawings. The actual external pipe diameter and connection arrangement may also be needed to establish the correct opening dimensions.

If you are working from an existing manufacturer’s product reference or council detail, include this with your enquiry. You do not need to have every measurement confirmed before contacting us.

Design and Installation

Wingwall dimensions, reinforcement, concrete specifications and other structural details need to be established for the applicable project design.

Installation must follow the relevant engineering drawings and site requirements, including foundation preparation, bedding, lifting, pipe connections, backfilling and any necessary scour protection.

Manufacturing and Availability

Wingwalls are primarily made to order at Wade’s Dargaville manufacturing facility. Manufacturing feasibility, lead times and delivery arrangements can be discussed once the requirements are known.

Contact Wade with your project information to request a quotation.

Need pricing or advice on this product?

Talk to our team about suitability, delivery and pricing for your site.